Victron Energy GEL Solar 12 V 130 Ah Ackumulator

VRLA technology VRLA stands for Valve Regulated Lead Acid, which means that the batteries are sealed. Gas will escape through the safety valves only in case of overcharging or cell failure. VRLA batteries are maintenance free for life. ...
Extra gifts
Få en gratis gåva genom att köpa denna produkt
Extra rabatt på denna produkt med kod EXTRA5  
Pris efter kodanvändning:  5,062,55 kr 
I lager för webbutik 1 stycke
Skickas idag ,
2024-05-10
Ackumulator Victron Energy GEL Solar 12 V 130 Ah Ackumulator

Victron Energy GEL Solar 12 V 130 Ah Ackumulator

5,329 kr

Produktkod: BAT412121104 | ID: 393391

Victron Energy GEL Solar 12 V 130 Ah Ackumulator

  • VRLA technology
  • VRLA stands for Valve Regulated Lead Acid, which means that the batteries are sealed. Gas will escape through the safety valves only in case of overcharging or cell failure. VRLA batteries are maintenance free for life.

    • Sealed (VRLA) AGM Batteries

    AGM stands for Absorbent Glass Mat. In these batteries the electrolyte is absorbed into a glass-fibre mat between the plates by capillary action. AGM batteries are more suitable for short-time delivery of very high currents (engine starting) than gel batteries.

    • Sealed (VRLA) Gel Batteries

    Here the electrolyte is immobilized as gel. Gel batteries in general have a longer service life and better cycle capacity than AGM batteries.

    • Low Self-Discharge

    Because of the use of lead calcium grids and high purity materials, Victron VRLA batteries can be stored during long periods of time without recharge. The rate of self-discharge is less than 2 % per month at 20 °C. The self discharge doubles for every increase in temperature by 10 °C. Victron VRLA batteries can therefore be stored for up to a year without recharging, if kept under cool conditions.

    • Exceptional Deep Discharge Recovery

    Victron VRLA batteries have exceptional discharge recovery, even after deep or prolonged discharge. Nevertheless repeatedly deep and prolonged discharge has a very negative effect on the service life of all lead acid batteries, Victron batteries are no exception.

    • Battery Discharging Characteristics

    The rated capacity of Victron AGM and Gel Deep Cycle batteries refers to 20 h discharge, in other words: a discharge current of 0,05 C. The rated capacity of Victron Tubular Plate Long Life batteries refers to 10 h discharge. The effective capacity decreases with increasing discharge current. AGM deep cycle batteries have excellent high current performance and are therefore recommended for high current applications such as engine starting. Due to their construction, Gel batteries have a lower effective capacity at high discharge currents. On the other hand, Gel batteries have a longer service life, both under float and cycling conditions.

     

    • Battery charging in case of cycle use: the 3-step charge curve

    The most common charge curve used to charge VRLA batteries in case of cyclic use is the 3-step charge curve, whereby a constant current phase (the bulk phase) is followed by two constant voltage phases (absorption and float).During the absorption phase the charge voltage is kept at a relatively high level in order to fully recharge the battery within reasonable time. The third and last phase is the float phase: the voltage is lowered to standby level, sufficient to compensate for self-discharge.

    Ytterligare beskrivning på ditt språk är inte tillgänglig ännu. Beskrivningen på engelska kan hjälpa.
    • The Victron four-step adaptive charge curve solves the 3 main problems of the 3-step curve:

    • Battery Safe Mode
    In order to prevent excessive gassing, Victron has invented the ‘Battery Safe Mode’. The Battery Safe Mode will limit the rate of voltage increase once the gassing voltage has been reached. Research has shown that this will reduce internal gassing to a safe level.

    • Variable absorption time
    Based on the duration of the bulk stage, the charger calculates how long the absorption time should be in order to fully charge the battery. If the bulk time is short, this means the battery was already charged and the resulting absorption time will also be short, whereas a longer bulk time will also result in a longer absorption time.

    • Storage mode
    After completion of the absorption period the battery should be fully charged, and the voltage is lowered to the float or standby level. If no discharge occurs during the next 24 hours, the voltage is reduced even further and the battery goes into storage mode. The lower storage voltage reduces corrosion of the positive plates. Once every week the charge voltage is increased to the absorption level for a short period to compensate for selfdischarge (Battery Refresh mode).

    Parametrar och specifikationer

    Info

    Batteriets livslängd

    6 månader


    Strömförsörjning

    Spänning

    12 V

    Batteriets kapacitet

    Ström

    36 A

    Strömförsörjning

    Ingen


    Tillbehör

    UK/EU Strömförsörjning ingår

    Nej


    Dimensioner och vikt

    Nettovikt (kg)

    38


    Land

    Tillverkad i

    Nederländerna